dc.descriptionWe present the status of the development of a dedicated high density ultra-cold neutron (UCN) source dedicated to the gravitational spectrometer GRANIT. The source employs superthermal conversion of cold neutrons to UCN in superfluid helium. Tests have shown that UCN produced inside the liquid can be extracted into vacuum. Furthermore a dedicated neutron selection channel was tested to maintain high initial density and extract only neutrons with a vertical velocity component 20 cm/s for the spectrometer. This new source would have a phase-space density of 0.18 cm-3(m/s)-3 for the spectrometer.
dc.descriptionISINN 15 conference proceeding Article has been replaced due to minor orthographic changes
dc.identifierhttps://arxiv.org/abs/0708.1373
dc.identifierhttp://arxiv.org/abs/0708.1373
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/136269
dc.subjectNuclear Experiment
dc.titleA source of ultra-cold neutrons for the gravitational spectrometer GRANIT