Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements

dc.creatorAkindinov, A.
dc.creatorGolovin, V.
dc.creatorMartemiyanov, A.
dc.creatorPetrov, V.
dc.creatorSmirnitskiy, A.
dc.creatorVoloshin, K.
dc.date2004-10-15
dc.date2004-12-02
dc.date.accessioned2026-07-07T05:52:55Z
dc.date.available2026-07-07T05:52:55Z
dc.descriptionPrinciples of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of applied voltages. Double-gap DRPCs have demonstrated the MIP registration efficiency of 97% and the time resolution of 180-200 ps. No changes in DRPC operation have been observed with test beam intensities up to 10^3 Hz/cm^2.
dc.description8 pages, 7 figures text formatting and figures updated for better performance slight corrections made in the text
dc.identifierhttps://arxiv.org/abs/physics/0410103
dc.identifierhttp://arxiv.org/abs/physics/0410103
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/86477
dc.subjectInstrumentation and Detectors
dc.titleDielectric Resistive Plate Chamber as a detector for time-of-flight measurements
dc.typetext