On the limited amplitude resolution of multipixel Geiger-mode APDs
| dc.creator | Stoykov, A. | |
| dc.creator | Musienko, Y. | |
| dc.creator | Kuznetsov, A. | |
| dc.creator | Reucroft, S. | |
| dc.creator | Swain, J. | |
| dc.date | 2007-06-05 | |
| dc.date.accessioned | 2026-07-07T10:36:03Z | |
| dc.date.available | 2026-07-07T10:36:03Z | |
| dc.description | The limited number of active pixels in a Geiger-mode Avalanche Photodiode (G-APD) results not only in a non-linearity but also in an additional fluctuation of its response. Both these effects are taken into account to calculate the amplitude resolution of an ideal G-APD, which is shown to be finite. As one of the consequences, the energy resolution of a scintillation detector based on a G-APD is shown to be limited to some minimum value defined by the number of pixels in the G-APD. | |
| dc.description | 5 pages, 3 figures | |
| dc.identifier | https://arxiv.org/abs/0706.0746 | |
| dc.identifier | http://arxiv.org/abs/0706.0746 | |
| dc.identifier | JINST2:P06005,2007 | |
| dc.identifier | doi:10.1088/1748-0221/2/06/P06005 | |
| dc.identifier.uri | http://salesiana.dossiersoluciones.com/handle/123456789/179927 | |
| dc.subject | Instrumentation and Detectors | |
| dc.title | On the limited amplitude resolution of multipixel Geiger-mode APDs | |
| dc.type | text |