Track Reconstruction and Alignment with the CMS Silicon Tracker

dc.creatorSchilling, F. -P.
dc.date2006-10-01
dc.date.accessioned2026-07-07T07:29:49Z
dc.date.available2026-07-07T07:29:49Z
dc.descriptionThis report presents recent results on track reconstruction and alignment with the silicon tracker of the CMS experiment at the LHC, obtained with a full detector simulation. After an overview of the layout of the tracker and its material budget, the baseline algorithm for track reconstruction is discussed. The performance of the track reconstruction and its dependence on misalignment is shown. The concept for alignment of the CMS tracker, using a laser alignment system as well as three different track-based alignment algorithms, is presented.
dc.descriptionPoster presented at the 33rd Intl. Conference on High Energy Physics, ICHEP 2006 (Moscow, July 2006)
dc.identifierhttps://arxiv.org/abs/physics/0610005
dc.identifierhttp://arxiv.org/abs/physics/0610005
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/118261
dc.subjectInstrumentation and Detectors
dc.subjectAccelerator Physics
dc.titleTrack Reconstruction and Alignment with the CMS Silicon Tracker