Measurement of the Neutron Lifetime Using a Proton Trap

dc.creatorDewey, M. S.
dc.creatorGilliam, D. M.
dc.creatorNico, J. S.
dc.creatorWietfeldt, F. E.
dc.creatorFei, X.
dc.creatorSnow, W. M.
dc.creatorGreene, G. L.
dc.creatorPauwels, J.
dc.creatorEykens, R.
dc.creatorLamberty, A.
dc.creatorVan Gestel, J.
dc.date2003-11-04
dc.date.accessioned2026-07-07T12:04:05Z
dc.date.available2026-07-07T12:04:05Z
dc.descriptionWe report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime: tau_n = 886.8 +/- 1.2[stat] +/- 3.2[sys] seconds. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.
dc.description5 pages, 4 figures
dc.identifierhttps://arxiv.org/abs/nucl-ex/0311006
dc.identifierhttp://arxiv.org/abs/nucl-ex/0311006
dc.identifierPhys.Rev.Lett.91:152302,2003
dc.identifierdoi:10.1103/PhysRevLett.91.152302
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/208016
dc.subjectNuclear Experiment
dc.titleMeasurement of the Neutron Lifetime Using a Proton Trap
dc.typetext

Files