An Improved Shashlyk Calorimeter

dc.creatorAtoian, G. S.
dc.creatorBritvich, G. I.
dc.creatorChernichenko, S. K.
dc.creatorDhawan, S.
dc.creatorIssakov, V. V.
dc.creatorKaravichev, O. V.
dc.creatorKaravicheva, T. L.
dc.creatorMarin, V. N.
dc.creatorPoblaguev, A. A.
dc.creatorShein, I. V.
dc.creatorSoldatov, A. P.
dc.creatorZeller, M. E.
dc.date2007-09-28
dc.date.accessioned2026-07-07T11:19:38Z
dc.date.available2026-07-07T11:19:38Z
dc.descriptionShashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction, selection of wave shifting fibers and photo-detectors, and development of a new scintillator with improved optical and mechanical properties are described. How the modules will perform in a large calorimeter was determined from prototype measurements. The experimentally determined characteristics of the calorimeter prototype show energy resolution of sigma_E/E=(1.96+-0.1)% \oplus (2.74+-0.05)%/sqrt{E}, time resolution of sigma_T = (72+-4)/sqrt{E} \oplus (14+-2)/E (ps), where photon energy E is given in GeV units and \oplus means a quadratic summation. A punch-through inefficiency of photon detection was measured to be ε= 5*10^{-5} (Θ>5 mrad).
dc.description29 pages, 21 figures
dc.identifierhttps://arxiv.org/abs/0709.4514
dc.identifierhttp://arxiv.org/abs/0709.4514
dc.identifierNucl.Instrum.Meth.A584:291-303,2008
dc.identifierdoi:10.1016/j.nima.2007.10.022
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/193750
dc.subjectInstrumentation and Detectors
dc.titleAn Improved Shashlyk Calorimeter
dc.typetext

Files