Low temperature dephasing in irradiated metallic wires

dc.creatorCapron, T.
dc.creatorNiimi, Y.
dc.creatorBaines, Y.
dc.creatorMailly, D.
dc.creatorLo, F. -Y.
dc.creatorMelnikov, A.
dc.creatorWieck, A. D.
dc.creatorSaminadayar, L.
dc.creatorBäuerle, C.
dc.date2007-11-12
dc.date2008-05-14
dc.date.accessioned2026-07-07T09:38:29Z
dc.date.available2026-07-07T09:38:29Z
dc.descriptionWe present phase coherence time measurements in quasi-one-dimensional Ag wires implanted with Ag$^{+}$ ions with an energy of $100 keV$. The measurements have been carried out in the temperature range from $100 mK$ up to $10 K$; this has to be compared with the Kondo temperature of iron in silver, i.e. $T_{K}^{Ag/Fe} \approx 4 K$, used in recent experiments on dephasing in Kondo systems\cite{mallet_prl_06,birge_prl_06}. We show that the phase coherence time is not affected by the implantation procedure, clearly proving that ion implantation process by itself \emph{does not lead to any extra dephasing} at low temperature.
dc.description4 pages, 4figures
dc.identifierhttps://arxiv.org/abs/0711.1810
dc.identifierhttp://arxiv.org/abs/0711.1810
dc.identifierdoi:10.1103/PhysRevB.77.033102
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/160823
dc.subjectMesoscale and Nanoscale Physics
dc.titleLow temperature dephasing in irradiated metallic wires
dc.typetext

Files