Frequency-domain "single-shot" (FDSS) transient absorption spectroscopy using a variable-length grating pair compressor

dc.creatorShkrob, Ilya A.
dc.creatorOulianov, Dmitri A.
dc.creatorCrowell, Robert A.
dc.date2004-07-02
dc.date.accessioned2026-07-07T05:52:12Z
dc.date.available2026-07-07T05:52:12Z
dc.descriptionSingle-shot ultrafast spectroscopy based on the frequency encoding of transient absorbance kinetics (FDSS) is demonstrated. These kinetics are sampled spectrally using linearly chirped pulses derived from a Ti:sapphire laser. A variable length grating pair compressor is used to provide group velocity dispersion out to -1.6 ps^2 and achieve the sampling of 512 channels per a 2-to-160 ps window with sensitivity > 5e-4. The possibilities of FDSS are illustrated with studies of three photon ionization of liquid water and one-photon excitation of a thin-film
dc.description23 pages + 8 figures
dc.identifierhttps://arxiv.org/abs/physics/0407017
dc.identifierhttp://arxiv.org/abs/physics/0407017
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/86245
dc.subjectOptics
dc.subjectClassical Physics
dc.titleFrequency-domain "single-shot" (FDSS) transient absorption spectroscopy using a variable-length grating pair compressor
dc.typetext

Files

Collections