In-beam tests of scintillating fibre detectors at MAMI and at GSI
| dc.creator | Achenbach, P. | |
| dc.creator | Gayoso, C. Ayerbe | |
| dc.creator | Bernauer, J. C. | |
| dc.creator | Böhm, R. | |
| dc.creator | Distler, M. O. | |
| dc.creator | Doria, L. | |
| dc.creator | de la Paz, M. Gómez Rodríguez | |
| dc.creator | Merkel, H. | |
| dc.creator | Müller, U. | |
| dc.creator | Nungesser, L. | |
| dc.creator | Pochodzalla, J. | |
| dc.creator | Majos, S. Sánchez | |
| dc.creator | Schlimme, B. S. | |
| dc.creator | Walcher, Th. | |
| dc.creator | Weinriefer, M. | |
| dc.creator | Debenjak, L. | |
| dc.creator | Potokar, M. | |
| dc.creator | Sirca, S. | |
| dc.creator | Kavatsyuk, M. | |
| dc.creator | Lepyoshkina, O. | |
| dc.creator | Minami, S. | |
| dc.creator | Nakajima, D. | |
| dc.creator | Rappold, C. | |
| dc.creator | Saito, T. R. | |
| dc.creator | Schardt, D. | |
| dc.creator | Träger, M. | |
| dc.creator | Iwase, H. | |
| dc.creator | Ajimura, S. | |
| dc.creator | Sakaguchi, A. | |
| dc.creator | Mizoi, Y. | |
| dc.date | 2008-02-20 | |
| dc.date.accessioned | 2026-07-07T11:56:12Z | |
| dc.date.available | 2026-07-07T11:56:12Z | |
| dc.description | The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The variation in the measured energy deposition was Delta E/E= 15-20% (FWHM) for carbon ions. In addition, the energy response to p/pi/d particles was studied. Based on the good detector performance fibre hodoscopes will be constructed for the KAOS/A1 spectrometer at MAMI and for the HypHI experiment at GSI. | |
| dc.description | submitted to Nucl. Instrum. Meth. A | |
| dc.identifier | https://arxiv.org/abs/0802.2830 | |
| dc.identifier | http://arxiv.org/abs/0802.2830 | |
| dc.identifier | Nucl.Instrum.Meth.A593:353-360,2008 | |
| dc.identifier | doi:10.1016/j.nima.2008.05.017 | |
| dc.identifier.uri | http://salesiana.dossiersoluciones.com/handle/123456789/205503 | |
| dc.subject | Nuclear Experiment | |
| dc.title | In-beam tests of scintillating fibre detectors at MAMI and at GSI | |
| dc.type | text |