Estimation of Power Balance in Steady State LHCD Discharges on TRIAM-1M

dc.creatorSugata, Tomoya
dc.creatorHanada, K.
dc.creatorImamura, N.
dc.creatorSakamoto, M.
dc.creatorZushi, H.
dc.creatorIdei, H.
dc.creatorIyomasa, A.
dc.creatorKawasaki, S.
dc.creatorSato, K.
dc.creatorNakashima, H.
dc.creatorNakamura, K.
dc.creatorHasegawa, M.
dc.creatorHigashijima, A.
dc.date2004-10-23
dc.date.accessioned2026-07-07T05:53:12Z
dc.date.available2026-07-07T05:53:12Z
dc.descriptionOn TRIAM-1M, a long duration discharge for more than 5 h was achieved successfully by fully non-inductive lower hybrid current drive. Heat load distribution to the plasma facing components (PFCs) in the 5 h discharge was investigated by using calorimetric measurements. The injected RF power was coincident with the total amount of heat load to PFCs estimated by calorimetric measurement. The power balance including the portion of direct loss power of fast electron, heat flux due to the charge exchange process was able to be estimated in this long duration discharge.
dc.description12th International Congress on Plasma Physics, 25-29 October 2004, Nice (France)
dc.identifierhttps://arxiv.org/abs/physics/0410232
dc.identifierhttp://arxiv.org/abs/physics/0410232
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/86559
dc.subjectPlasma Physics
dc.titleEstimation of Power Balance in Steady State LHCD Discharges on TRIAM-1M
dc.typetext

Files