Improved Time Domain Method to Measure Near-Field Distribution of Buried-Object

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Description

The paper analyses the ground antenna echo using microwave frequency detector and high speed sampling technology and a new method detecting buried object in time domain near-field is presented. The method detecting particular reflection echo frequency of microwave pulse via digital signal processing is to reduce the false alarm rate. Simulation results show that this method has advantages of easy identification and high precision.
8 pages, 5 figures