| dc.description | Two simple mathematical models of electric neuro-stimulation are derived and discussed. It is found that the common injected-charge model is less realistic than a model, in which a latency period, which follows after a short electric pulse, plays a role as important as the electric pulse. A stimulation signal is proposed that takes advantage of these findings and calls for experimental testing. | |
| dc.description | 10 pages, 4 figures | |