The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit
| dc.creator | Campbell, M. | |
| dc.creator | Chefdeville, M. | |
| dc.creator | Colas, P. | |
| dc.creator | Colijn, A. P. | |
| dc.creator | Fornaini, A. | |
| dc.creator | Giomataris, Y. | |
| dc.creator | van der Graaf, H. | |
| dc.creator | Heijne, E. H. M | |
| dc.creator | Kluit, P. | |
| dc.creator | Llopart, X. | |
| dc.creator | Schmitz, J. | |
| dc.creator | Timmermans, J. | |
| dc.creator | Visschers, J. L. | |
| dc.date | 2004-09-09 | |
| dc.date.accessioned | 2026-07-07T12:00:20Z | |
| dc.date.available | 2026-07-07T12:00:20Z | |
| dc.description | A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays. | |
| dc.description | 15 pages, 9 included postscript figures, 5 separate jpeg figures, submitted to Nucl. Instr. and Meth. A. A complete postscript version with high resolution figures 1, 3, 11, 12 and 14 can be found at http://www.nikhef.nl/~i06/RandD/final/letter4.ps | |
| dc.identifier | https://arxiv.org/abs/physics/0409048 | |
| dc.identifier | http://arxiv.org/abs/physics/0409048 | |
| dc.identifier | Nucl.Instrum.Meth.A540:295-304,2005 | |
| dc.identifier | doi:10.1016/j.nima.2004.11.036 | |
| dc.identifier.uri | http://salesiana.dossiersoluciones.com/handle/123456789/206824 | |
| dc.subject | Instrumentation and Detectors | |
| dc.subject | High Energy Physics - Experiment | |
| dc.title | The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit | |
| dc.type | text |