The VLQ Calorimeter of H1 at HERA: A Highly Compact Device for Measurements of Electrons and Photons under Very Small Scattering Angles

dc.creatorStellberger, A.
dc.creatorMeier, K.
dc.creatorNiedermaier, O.
dc.creatorNix, O.
dc.creatorSchmitt, K.
dc.creatorStiewe, J.
dc.creatorWeber, M.
dc.creatorFerencei, J.
dc.creatorKrivan, F.
dc.creatorSpalek, J.
dc.date2003-05-16
dc.date.accessioned2026-07-07T11:32:49Z
dc.date.available2026-07-07T11:32:49Z
dc.descriptionIn 1998, the detector H1 at HERA has been equipped with a small backward spectrometer, the Very Low Q^2 (VLQ) spectrometer comprising a silicon tracker, a tungsten - scintillator sandwich calorimeter, and a Time-of-Flight system. The spectrometer was designed to measure electrons scattered under very low angles, equivalent to very low squared four - momentum transfers Q^2, and high energy photons with good energy and spatial resolution. The VLQ was in operation during the 1999 and 2000 run periods. This paper describes the design and construction of the VLQ calorimeter, a compact device with a fourfold projective energy read-out, and its performance during test runs and in the experiment.
dc.description32 pages, 25 figures, 2 tables (To be submitted to Nucl. Instrum. Meth. A)
dc.identifierhttps://arxiv.org/abs/physics/0305070
dc.identifierhttp://arxiv.org/abs/physics/0305070
dc.identifierNucl.Instrum.Meth.A515:543-562,2003
dc.identifierdoi:10.1016/j.nima.2003.08.111
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/197731
dc.subjectInstrumentation and Detectors