Multiple hits in wire chambers and other particle detectors

dc.creatorVan Esch, Patrick
dc.date2007-06-08
dc.date.accessioned2026-07-07T10:56:07Z
dc.date.available2026-07-07T10:56:07Z
dc.descriptionWe propose an analysis of the dead time losses in counting imaging detectors such as MWPC which can resolve $k$ simultaneous hits, and analyze in more detail an $X-Y$ detector which has a third wire set which allows for the recognition of simultaneous impacts.
dc.description15 pages, 4 figures
dc.identifierhttps://arxiv.org/abs/0706.1136
dc.identifierhttp://arxiv.org/abs/0706.1136
dc.identifierJINST2:P09004,2007
dc.identifierdoi:10.1088/1748-0221/2/09/P09004
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/186304
dc.subjectInstrumentation and Detectors
dc.titleMultiple hits in wire chambers and other particle detectors
dc.typetext

Files