Design of the 7 MeV/u, 217 MHz Injector Linac for the Proposed Ion Beam Facility for Cancer Therapy at the Clinic in Heidelberg

dc.creatorSchlitt, B.
dc.creatorBechtold, A.
dc.creatorRatzinger, U.
dc.creatorSchempp, A.
dc.date2000-08-18
dc.date.accessioned2026-07-07T05:44:36Z
dc.date.available2026-07-07T05:44:36Z
dc.descriptionA dedicated clinical synchrotron facility for cancer therapy using energetic proton and ion beams (C, He and O) has been designed at GSI for the Radiologische Universitaetsklinik at Heidelberg, Germany. The design of the injector linac is presented. Suitable ion sources are discussed and results of ion source test measurements are reported. The LEBT allows for switching between two ion sources. A short RFQ accelerates the ions from 8 keV/u to 400 keV/u. It is followed by a very compact beam matching section and a 3.8 m long IH-type drift tube linac for the acceleration to 7 MeV/u. Both rf structures are designed for a resonance frequency of 216.816 MHz and for ion mass-to-charge ratios up to A/q = 3 (12C4+, (H_3)+, 3He+, 16O6+).
dc.descriptionContribution to the LINAC2000 Proceedings, Paper ID: MOD10
dc.identifierhttps://arxiv.org/abs/physics/0008148
dc.identifierhttp://arxiv.org/abs/physics/0008148
dc.identifiereConf C000821 (2000) MOD10
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/83699
dc.subjectAccelerator Physics
dc.titleDesign of the 7 MeV/u, 217 MHz Injector Linac for the Proposed Ion Beam Facility for Cancer Therapy at the Clinic in Heidelberg
dc.typetext

Files

Collections