Non-compensation of an Electromagnetic Compartment of a Combined Calorimeter

dc.creatorKulchitsky, Y. A.
dc.creatorKuzmin, M. V.
dc.creatorVinogradov, V. B.
dc.date1999-11-23
dc.date.accessioned2026-07-07T03:38:11Z
dc.date.available2026-07-07T03:38:11Z
dc.descriptionThe method of extraction of the $e/h$ ratio, the degree of non-compensation, of the electromagnetic compartment of the combined calorimeter is suggested. The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data. This value agrees with the prediction that $e/h > 1.7$ for this electromagnetic calorimeter.
dc.descriptionLATEX, 17 pages, 7 figures
dc.identifierhttps://arxiv.org/abs/hep-ex/9911033
dc.identifierhttp://arxiv.org/abs/hep-ex/9911033
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/38427
dc.subjectHigh Energy Physics - Experiment
dc.titleNon-compensation of an Electromagnetic Compartment of a Combined Calorimeter
dc.typetext

Files

Collections