Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

dc.creatorAharrouche, M.
dc.creatorColas, J.
dc.creatorDi Ciaccio, L.
dc.creatorKacimi, M. El
dc.creatorGaumer, O.
dc.creatorGouanere, M.
dc.creatorGoujdami, D.
dc.creatorLafaye, R.
dc.creatorLaplace, S.
dc.creatorManer, C. Le
dc.creatorNeukermans, L.
dc.creatorPerrodo, P.
dc.creatorPoggioli, L.
dc.creatorPrieur, D.
dc.creatorPrzysiezniak, H.
dc.creatorSauvage, G.
dc.creatorWingerter-Seez, I.
dc.creatorZitoun, R.
dc.creatorLanni, F.
dc.creatorLu, L.
dc.creatorMa, H.
dc.creatorpalan, S. Rajago
dc.creatorTakai, H.
dc.creatorBelymam, A.
dc.creatorBenchekroun, D.
dc.creatorHakimi, M.
dc.creatorHoummada, A.
dc.creatorGao, Y.
dc.creatorStroynowsk i, R.
dc.creatorAleksa, M.
dc.creatorCarli, T.
dc.creatorFassnacht, P.
dc.creatorGianotti, F.
dc.creatorHervas, L.
dc.creatorLampl, W.
dc.creatorCollot, J.
dc.creatorstachy, J. Y. Ho
dc.creatorLedroit-Guillon, F.
dc.creatorMalek, F.
dc.creatorMartin, P.
dc.creatorViret, S.
dc.creatorLeltchouk, M.
dc.creatorParsons, J. A.
dc.creatorSimion, S.
dc.creatorBarreiro, F.
dc.creatorDel Peso, J.
dc.creatorLabarga, L.
dc.creatorOliver, C.
dc.creatorRodier, S.
dc.creatorBarrillon, P.
dc.creatorouk, C. Bench
dc.creatorDjama, F.
dc.creatorHubaut, F.
dc.creatorMonnier, E.
dc.creatorPralavorio, P.
dc.creatorSauvage, D.
dc.creatorSerfon, C.
dc.creatorTisserant, S.
dc.creatorToth, J.
dc.creatorBanfi, D.
dc.creatorCarminati, L.
dc.creatorCavalli, D.
dc.creatorCosta, G.
dc.creatorDelmastro, M.
dc.creatorFanti, M.
dc.creatorMandell i, L.
dc.creatorMazzanti, M.
dc.creatorTartarelli, G. F.
dc.creatorKotov, K.
dc.creatorMaslennikov, A.
dc.creatorPospelov, G.
dc.creatorTikhonov, Yu.
dc.creatorBourdarios, C.
dc.creatorFayard, L.
dc.creatorFournier, D.
dc.creatorIconomidou-Fayard, L.
dc.creatorKado, M.
dc.creatorParrour, G.
dc.creatorPuzo, P.
dc.creatorRousseau, D.
dc.creatorSacco, R.
dc.creatorSerin, L.
dc.creatorUnal, G.
dc.creatorZerwas, D.
dc.creatorDekhissi, B.
dc.creatorDerkaoui, J.
dc.creatorKharrim, A. El
dc.creatorMaaroufi, F.
dc.creatorCleland, W.
dc.creatorLacour, D.
dc.creatorLaforge, B.
dc.creatorNikolic-Audit, I.
dc.creatorSchwemling, Ph.
dc.creatorzlane, H. Gha
dc.creatorMoursli, R. Cherkaoui El
dc.creatorFakhr-Eddine, A. Idrissi
dc.creatorBoonekamp, M.
dc.creatorKerschen, N.
dc.creatorsoulie, B. Man
dc.creatorMeyer, P.
dc.creatorSchwindlingy, J.
dc.creatorLund-Jensen, B.
dc.date2007-09-07
dc.date.accessioned2026-07-07T11:19:12Z
dc.date.available2026-07-07T11:19:12Z
dc.descriptionThe construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.
dc.descriptionAccepted by NIM A
dc.identifierhttps://arxiv.org/abs/0709.1094
dc.identifierhttp://arxiv.org/abs/0709.1094
dc.identifierNucl.Instrum.Meth.A582:429-455,2007
dc.identifierdoi:10.1016/j.nima.2007.08.157
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/193605
dc.subjectInstrumentation and Detectors
dc.titleResponse Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter
dc.typetext

Files

Collections