Precision frequency measurement of visible intercombination lines of strontium
| dc.creator | Ferrari, G. | |
| dc.creator | Cancio, P. | |
| dc.creator | Drullinger, R. | |
| dc.creator | Giusfredi, G. | |
| dc.creator | Poli, N. | |
| dc.creator | Prevedelli, M. | |
| dc.creator | Toninelli, C. | |
| dc.creator | Tino, G. M. | |
| dc.date | 2003-09-01 | |
| dc.date | 2003-11-06 | |
| dc.date.accessioned | 2026-07-07T06:26:09Z | |
| dc.date.available | 2026-07-07T06:26:09Z | |
| dc.description | We report the direct frequency measurement of the visible 5s$^2$ $^1$S$_0$-5s 5p$^3$P$_1$ intercombination line of strontium that is considered a possible candidate for a future optical frequency standard. The frequency of a cavity-stabilized laser is locked to the saturated fluorescence in a thermal Sr atomic beam and is measured with an optical-frequency comb-generator referenced to the SI second through a GPS signal. The $^{88}$Sr transition is measured to be at 434 829 121 311 (10) kHz. We measure also the $^{88}$Sr-$^{86}$Sr isotope shift to be 163 817.4 (0.2) kHz. | |
| dc.description | 4 pages, 4 figures. To be published on Phys. Rev. Lett. To be published on Phys. Rev. Lett | |
| dc.identifier | https://arxiv.org/abs/physics/0309014 | |
| dc.identifier | http://arxiv.org/abs/physics/0309014 | |
| dc.identifier | Phys. Rev. Lett. 91, 243002 (2003) | |
| dc.identifier | doi:10.1103/PhysRevLett.91.243002 | |
| dc.identifier.uri | http://salesiana.dossiersoluciones.com/handle/123456789/97025 | |
| dc.subject | Atomic Physics | |
| dc.title | Precision frequency measurement of visible intercombination lines of strontium | |
| dc.type | text |