Three dimensional image correlation from X-Ray computed tomography of solid foam

dc.creatorRoux, Stephane
dc.creatorHild, François
dc.creatorViot, Philippe
dc.creatorBernard, Dominique
dc.date2007-12-17
dc.date.accessioned2026-07-07T08:49:37Z
dc.date.available2026-07-07T08:49:37Z
dc.descriptionA new methodology is proposed to estimate 3D displacement fields from pairs of images obtained from X-Ray Computed Micro Tomography (XCMT). Contrary to local approaches, a global approach is followed herein that evaluates {\em continuous} displacement fields. Although any displacement basis could be considered, the procedure is specialized to finite element shape functions. The method is illustrated with the analysis of a compression test on a polypropylene solid foam (independently studied in a companion paper). A good stability of the measured displacement field is obtained for cubic element sizes ranging from 16 voxels to 6 voxels.
dc.descriptionnombre de pages = 34
dc.identifierhttps://arxiv.org/abs/0712.2642
dc.identifierhttp://arxiv.org/abs/0712.2642
dc.identifierComposites A: Applied Science and Manufacturing (2007) 0
dc.identifierdoi:10.1016/j.physletb.2003.10.071
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/144366
dc.subjectClassical Physics
dc.titleThree dimensional image correlation from X-Ray computed tomography of solid foam
dc.typetext

Files