100 ps time-of-flight resolution of Dielectric Resistive Plate Chamber

dc.creatorAkindinov, A.
dc.creatorGolovin, V.
dc.creatorMartemiyanov, A.
dc.creatorPetrov, V.
dc.creatorPlotnikov, V.
dc.creatorSmirnitsky, A.
dc.creatorVoloshin, K.
dc.date2005-02-21
dc.date.accessioned2026-07-07T05:54:13Z
dc.date.available2026-07-07T05:54:13Z
dc.descriptionTime of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with different applied voltages, discriminating thresholds and beam intensities. It may be stated that the time-of-flight resolution of gaseous detectors developed within the ALICE experiment has reached the level of the best known scintillation counters.
dc.description5 pages, 7 figures
dc.identifierhttps://arxiv.org/abs/physics/0502111
dc.identifierhttp://arxiv.org/abs/physics/0502111
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/86888
dc.subjectInstrumentation and Detectors
dc.title100 ps time-of-flight resolution of Dielectric Resistive Plate Chamber
dc.typetext