Limits to the sensitivity of a low noise compact atomic gravimeter

dc.creatorGouët, J. Le
dc.creatorMehlstäubler, Tanja
dc.creatorKim, Jaewan
dc.creatorMerlet, Sébastien
dc.creatorClairon, Andre
dc.creatorLandragin, Arnaud
dc.creatorSantos, Franck Pereira Dos
dc.date2008-01-08
dc.date.accessioned2026-07-07T12:24:07Z
dc.date.available2026-07-07T12:24:07Z
dc.descriptionA detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of $1.4\times 10^{-8}$g at 1s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the AC acceleration signal measured by a low noise seismometer.
dc.description30 pages, 14 figures
dc.identifierhttps://arxiv.org/abs/0801.1270
dc.identifierhttp://arxiv.org/abs/0801.1270
dc.identifierApplied Physics B: Lasers and Optics 92, 2 (2008) 133-144
dc.identifierdoi:10.1007/s00340-008-3088-1
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/214223
dc.subjectAtomic Physics
dc.titleLimits to the sensitivity of a low noise compact atomic gravimeter
dc.typetext

Files