Study of Low beta-y Straight Section in SPEAR 3

dc.creatorNosochkov, Y.
dc.creatorCorbett, J.
dc.creatorRabedeau, T.
dc.date2001-06-20
dc.date.accessioned2026-07-07T11:32:47Z
dc.date.available2026-07-07T11:32:47Z
dc.descriptionThe SPEAR 3 light source has two 7.6 m straight sections one of which is available for new insertion devices (ID). By reducing the vertical beta function at the center of the straight from 9.8 m to 1.5 m, the beam size can be decreased from 44 to 17 microns to reduce the ID gap, but the ID length may be limited by the increased beta-y variation in the ID. Alternatively, a ``double waist'' optics with two symmetric low beta-y locations and a chicane may be considered to implement two IDs. In this paper, we discuss the low beta-y optics, effects on the beam dynamic aperture, and the ID parameters needed to maximize photon flux density and brightness while maintaining electron beam lifetime.
dc.descriptionPAC2001, 4 pages
dc.identifierhttps://arxiv.org/abs/physics/0106058
dc.identifierhttp://arxiv.org/abs/physics/0106058
dc.identifierConf.Proc.C0106181:2659-2661,2001
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/197719
dc.subjectAccelerator Physics
dc.titleStudy of Low beta-y Straight Section in SPEAR 3
dc.typetext

Files

Collections