Identification of photons in double beta-decay experiments using segmented germanium detectors - studies with a GERDA Phase II prototype detector

dc.creatorAbt, I.
dc.creatorCaldwell, A.
dc.creatorKröninger, K.
dc.creatorLiu, J.
dc.creatorLiu, X.
dc.creatorMajorovits, B.
dc.date2007-01-04
dc.date.accessioned2026-07-07T11:23:49Z
dc.date.available2026-07-07T11:23:49Z
dc.descriptionThe sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation. Segmented germanium detectors can be used to identify photons and thus reduce this background component. The GERmanium Detector Array, GERDA, will use highly segmented germanium detectors in its second phase. The identification of photonic events is investigated using a prototype detector. The results are compared with Monte Carlo data.
dc.description20 pages, 7 figures, to be submitted to NIM-A
dc.identifierhttps://arxiv.org/abs/nucl-ex/0701005
dc.identifierhttp://arxiv.org/abs/nucl-ex/0701005
dc.identifierNucl.Instrum.Meth.A583:332-340,2007
dc.identifierdoi:10.1016/j.nima.2007.09.017
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/195022
dc.subjectNuclear Experiment
dc.titleIdentification of photons in double beta-decay experiments using segmented germanium detectors - studies with a GERDA Phase II prototype detector
dc.typetext

Files