'Shut down' of an atom laser

dc.creatorRobins, N. P.
dc.creatorMorrison, A. K.
dc.creatorHope, J. J.
dc.creatorClose, J. D.
dc.date2005-01-31
dc.date.accessioned2026-07-07T03:03:31Z
dc.date.available2026-07-07T03:03:31Z
dc.descriptionWe present experimental results demonstrating that the flux of a continuous atom laser beam cannot be arbitrarily increased by increasing the strength of output-coupling. We find that a state changing output-coupler for a continuous atom laser switches off as the output-coupling strength, parameterized by the Rabi frequency, is increased above a critical value of four times the radial trapping frequency. In addition, we find that the continuous atom laser has large classical fluctuations when the Rabi frequency is greater than the radial trapping frequency, due to the output-coupling populating all accessible Zeeman states. The numerical solution of a one-dimensional 5-state Gross-Pitaevskii model for the atom laser is in good qualitative agreement with the experiment.
dc.description4 pages, 5 figures
dc.identifierhttps://arxiv.org/abs/cond-mat/0501747
dc.identifierhttp://arxiv.org/abs/cond-mat/0501747
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/25781
dc.subjectOther Condensed Matter
dc.title'Shut down' of an atom laser
dc.typetext

Files

Collections