Comment on "Test of constancy of speed of light with rotating cryogenic optical resonators"

dc.creatorTobar, Michael E.
dc.creatorWolf, Peter
dc.creatorStanwix, Paul L.
dc.date2006-01-24
dc.date.accessioned2026-07-07T06:59:58Z
dc.date.available2026-07-07T06:59:58Z
dc.descriptionA recent experiment by Antonini et. al. [Phys. Rev. A {\bf 71}, 050101R 2005], set new limits on Lorentz violating parameters in the frame-work of the photon sector of the Standard Model Extension (SME), $\tildeκ_{e-}^{ZZ}$, and the Robertson-Mansouri-Sexl (RMS) framework, $β-δ-1/2$. The experiment had significant systematic effects caused by the rotation of the apparatus which were only partly analysed and taken into account. We show that this is insufficient to put a bound on $\tildeκ_{e-}^{ZZ}$ and the bound on $β-δ-1/2$ represents a five-fold improvement not a ten-fold improvement as claimed. (For reply see Phys. Rev. A 72, 066102 (2005) DOI: 10.1103/PhysRevA.72.066102)
dc.description2 pages
dc.identifierhttps://arxiv.org/abs/physics/0601186
dc.identifierhttp://arxiv.org/abs/physics/0601186
dc.identifierPhys.Rev. A72 (2005) 066101
dc.identifierdoi:10.1103/PhysRevA.72.066101
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/107936
dc.subjectClassical Physics
dc.subjectGeneral Relativity and Quantum Cosmology
dc.subjectHigh Energy Physics - Phenomenology
dc.titleComment on "Test of constancy of speed of light with rotating cryogenic optical resonators"
dc.typetext

Files