Vibration diagnostics instrumentation for ILC

dc.creatorBertolini, A.
dc.date2007-07-03
dc.date.accessioned2026-07-07T10:56:33Z
dc.date.available2026-07-07T10:56:33Z
dc.descriptionThe future e-e+ 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper.
dc.description7 pages, 6 figures, this is a review article which will appear in a special issue of Measurement Science and Technology on high energy particle accelerator technology
dc.identifierhttps://arxiv.org/abs/0707.0374
dc.identifierhttp://arxiv.org/abs/0707.0374
dc.identifierMeasur.Sci.Tech.18:2293-2298,2007
dc.identifierdoi:10.1088/0957-0233/18/8/002
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/186449
dc.subjectInstrumentation and Detectors
dc.subjectAccelerator Physics
dc.titleVibration diagnostics instrumentation for ILC
dc.typetext

Files