dc.descriptionOver the past decade, dust particulate contamination has increasingly become an area of concern within the fusion research community. In a burning plasma machine design like the International Thermonuclear Experimental Reactor (ITER), dust contamination presents problems for diagnostic integration and may contribute to tritium safety issues. Additionally due to ITER design, such dust contamination problems are projected to become of even greater concern due to dust/wall interactions and possible instabilities created within the plasma by such particulates. Since the dynamics of such dust can in general be explained employing a combination of the ion drag, Coulomb force, and ion pre-sheath drifts, recent research in complex (dusty) plasma physics often offers unique insights for this research area. This paper will discuss the possibility of how experimental observations of the dust and plasma parameters within a GEC rf Reference Cell might be employed to diagnose conditions within fusion reactors, hopefully providing insight into possible mechanisms for dust detection and removal.