Influence of gas flow rate on liquid distribution in trickle-beds using perforated plates as liquid distributors

dc.creatorLlamas, Juan-David
dc.creatorLesage, François
dc.creatorWild, Gabriel
dc.date2008-05-27
dc.date.accessioned2026-07-07T12:30:44Z
dc.date.available2026-07-07T12:30:44Z
dc.descriptionTwo wire mesh tomography devices and a liquid collector were used to study the influence of the gas flow rate on liquid distribution when fluids distribution on top of the reactor is ensured by a perforated plate. In opposition to most of the studies realized by other authors, conditions in which the gas has a negative impact in liquid distribution were evidenced. Indeed, the obtained results show that the influence of gas flow rate depends on the quality of the initial distribution, as the gas forces the liquid to "respect" the distribution imposed at the top of the reactor. Finally, a comparison between the two measuring techniques shows the limitations of the liquid collector and the improper conclusions to which its use could lead.
dc.identifierhttps://arxiv.org/abs/0805.4109
dc.identifierhttp://arxiv.org/abs/0805.4109
dc.identifierIndustrial and Engineering Chemistry Research 48, 1 (2009) 7-11
dc.identifierdoi:10.1021/ie8001155
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/216220
dc.subjectChemical Physics
dc.titleInfluence of gas flow rate on liquid distribution in trickle-beds using perforated plates as liquid distributors
dc.typetext