Optimization of the parameters in the RHIC single crystal heavy ion collimation

dc.creatorBiryukov, V. M.
dc.creatorChesnokov, Yu. A.
dc.creatorKotov, V. I.
dc.creatorTrbojevic, D.
dc.creatorStevens, A.
dc.date2001-11-29
dc.date.accessioned2026-07-07T03:34:54Z
dc.date.available2026-07-07T03:34:54Z
dc.descriptionIn the framework of the project to design and test a collimation system prototype using bent channeling crystal for cleaning of the RHIC heavy ion beam halo, we have studied the optimal length and bending angle of a silicon (110) single crystal proposed to be a primary element situated upstream of the traditional heavy amorphous collimator. Besides the matters of the channeling and collimation efficiency, we also looked into the impact the crystal may have on the non-channeled particles that go on circulating in the ring, so as to reduce the momentum offset of the particles scattered of the crystal.
dc.description8pp. Presented at the 1999 Particle Accelerator Conference, New York
dc.identifierhttps://arxiv.org/abs/hep-ex/0111093
dc.identifierhttp://arxiv.org/abs/hep-ex/0111093
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/37168
dc.subjectHigh Energy Physics - Experiment
dc.titleOptimization of the parameters in the RHIC single crystal heavy ion collimation
dc.typetext

Files

Collections