Electrostatic Background Forces due to Varying Contact Potentials in Casimir Experiments

dc.creatorLamoreaux, Steve K.
dc.date2008-08-06
dc.date2008-09-13
dc.date.accessioned2026-07-07T10:02:21Z
dc.date.available2026-07-07T10:02:21Z
dc.descriptionThe existence of a monotonic distance dependent contact potential between two plates in a Casimir experiment leads to an additional electrostatic force that is significantly different from the case of a constant potential. Such a varying potential can arise if there is a uniform gradient in the work function or contact potential across a plate, as opposed to random microscopic fluctuations associated with patch potentials. A procedure to compensate for this force is described for the case of an experiment where the electrostatic force is minimized at each measurement distance by applying a voltage between the plates. It is noted that the minimizing voltage is not the contact potential.
dc.description4 pages version 2 points out that the determined V_a should not be included in the energy derivative for the force
dc.identifierhttps://arxiv.org/abs/0808.0885
dc.identifierhttp://arxiv.org/abs/0808.0885
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/168947
dc.subjectQuantum Physics
dc.titleElectrostatic Background Forces due to Varying Contact Potentials in Casimir Experiments
dc.typetext