dc.descriptionThe performance of a two-phase Ar avalanche detector with CsI photocathode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapor above the liquid phase; the CsI photocathode was deposited on the first GEM. Successful detection of both primary scintillation and ionization signals, produced by beta-particles in liquid Ar, has for the first time been demonstrated in the two-phase avalanche mode.
dc.description4 pages, 8 figures. Presented at the 11th Vienna Conference on Instrumentation, Feb 19-24, 2007