Kinematic Calibration of the Orthoglide-Type Mechanisms

dc.creatorPashkevich, Anatoly
dc.creatorChablat, Damien
dc.creatorWenger, Philippe
dc.date2007-05-09
dc.date.accessioned2026-07-07T08:00:17Z
dc.date.available2026-07-07T08:00:17Z
dc.descriptionThe paper proposes a novel calibration approach for the Orthoglide-type mechanisms based on observations of the manipulator leg parallelism during motions between the prespecified test postures. It employs a low-cost measuring system composed of standard comparator indicators attached to the universal magnetic stands. They are sequentially used for measuring the deviation of the relevant leg location while the manipulator moves the TCP along the Cartesian axes. Using the measured differences, the developed algorithm estimates the joint offsets that are treated as the most essential parameters to be adjusted. The sensitivity of the measurement methods and the calibration accuracy are also studied. Experimental results are presented that demonstrate validity of the proposed calibration technique.
dc.identifierhttps://arxiv.org/abs/0705.1215
dc.identifierhttp://arxiv.org/abs/0705.1215
dc.identifierSymposium on Information Control Problems in Manufacturing (2006) 1-6
dc.identifier.urihttp://salesiana.dossiersoluciones.com/handle/123456789/128635
dc.subjectRobotics
dc.titleKinematic Calibration of the Orthoglide-Type Mechanisms
dc.typetext

Files

Collections