2026-07-072026-07-07http://salesiana.dossiersoluciones.com/handle/123456789/174929The advances in Charge Coupled Devices in one hand and the high resolution measurements of holographic technique on the other hand, we have adopted the method of digital real-time holographic interferometry for the diagnostics of high density plasma. The measured values of plasma electron density agree with the measurements from other techniques.3 pages 5 Figures (eps)Plasma PhysicsInstrumentation and DetectorsPlasma diagnostics using digital holographic interferometrytext